Air Medical Journal
Volume 27, Issue 2 , Pages 86-90 , March 2008

Evaluation of two oxygen face masks with special regard to inspiratory oxygen fraction (FiO2) for emergency use in rescue helicopters

  • Jochen Hinkelbein, MD, DESA

      Affiliations

    • Clinic for Anesthesiology and Intensive Care Medicine, Medical Faculty Mannheim, Ruprecht-Karls-University Heidelberg, University Hospital Mannheim, Mannheim, Germany.
    • Corresponding Author InformationAddress for correspondence: Jochen Hinkelbein, Clinic for Anesthesiology and Intensive Care Medicine, University Hospital Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
  • ,
  • Eckard Glaser, Dipl-Phys

      Affiliations

    • Viasys Healthcare GmbH, Hoechberg, Germany.

References 

  1. Jeffrey AA , Warren PM . Should we judge a mask by its cover? . Thorax . 1992;47:543–546
  2. Beecroft JM , Hanly PJ . Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: pilot study in oxygen-dependent patients . Can Respir J . 2006;13:247–252
  3. Brantigan JW . Efficiency of constant-flow oxygen masks for general aviation: a new method of mask evaluation . Aviat Space Environ Med . 1975;46:231–240
  4. Futrell JW , Moore JL . The OxyArmTM: a supplemental oxygen delivery device . Anesth Analg . 2006;102:491–494
  5. Hnatiuk OW , Moores LK , Thompson JC , Jones MD . Delivery of high concentrations of inspired oxygen via Tusk mask . Crit Care Med . 1998;26:1032–1035
  6. Tyczka Industriegase GmbH . Available at http://www.tig.de/medgase.htm Accessed January 23, 2007.
  7. Watersafety GmbH. Sauerstoff-Füllungen . Available at http://www.watersafety.net/o2tipps/do2filhtm Accessed January 23, 2007.
  8. Hinkelbein J , Glaser E , Doerrstein J , Genzwuerker HV . Oxygen delivery comparison of two constant-flow masks during flight to 6863 m . Aviat Space Environ Med . 2006;77:540–544
  9. Viasys Healthcare. Hi-Ox80 oxygen mask. Available at http://www.guggconsulting.com/summit_web/images/HiOx80.jpg. Accessed January 1, 2007.
  10. Waldau T , Larsen VH , Bonde J . Evaluation of five oxygen delivery devices in spontaneously breathing subjects by oxygraphy . Anaesthesia . 1998;53:256–263
  11. Sasaki H , Yamakage M , Iwasaki S , Mizuuchi M , Namiki A . Design of oxygen delivery systems influences both effectiveness and comfort in adult volunteers . Can J Anaesth . 2003;50:105–125
  12. Dinesen T , McDonald L , McDonald S , DuVall D . A comparison of the OxyArm oxygen delivery device and standard nasal cannulae in chronic obstructive pulmonary disease patients . Respir Care . 2003;48:120–123
  13. Jones HA , Turner SL , Hughes JMB . Performance of the large-reservoir oxygen mask (Ventimask) . Lancet . 1984;1(8392):1427–1431
  14. Costello RW , Liston R , McNicholas WT . Compliance at night with low flow oxygen therapy: a comparison of nasal cannulae and Venturi face masks . Thorax . 1995;50:405–406
  15. Mardimae A , Slessarev M , Han J , Sasano H , Sasano N , Azami T , et al.   Modified N95 mask delivers high inspired oxygen concentrations while effectively filtering aerosolized microparticles . Ann Emerg Med . 2006;48:391–399
  16. Hendricks DM , Pollock NW , Natoli MJ , Vann RD . Mountaineering oxygen mask performance at 4572 m . Aviat Space Environ Med . 2000;71:1142–1147
  17. Slessarev M , Somogyi R , Preiss D , Vesely A , Sasano H , Fisher JA . Efficiency of oxygen administration: sequential gas delivery versus “flow into a cone” methods . Crit Care Med . 2006;34:829–834

 Disclosure: This study was not sponsored by any of the manufacturers mentioned in the manuscript. J.H. received no financial support, payment or any other advantages from the manufacturers of the used medicine products. E.G. is employed at Viasys Healthcare GmbH, Hoechberg, Germany.

PII: S1067-991X(07)00171-X

doi: 10.1016/j.amj.2007.07.005

Air Medical Journal
Volume 27, Issue 2 , Pages 86-90 , March 2008